MicroLoop spirometer

Conduct portable spirometry

Our highly portable MicroLoop spirometer can be used in physician offices or for bedside testing of FVC and SVC.

Color-guided usability

A high-definition color touchscreen enables easy access to functions.

Full configuration

The system lets you select up to 41 indexes, including predicted values and languages.

On-screen convenience

Using full flow volume and volume time curves, you can inspect maneuvers while following test-quality screen prompts.

Convenient animation

With three computer animation incentive programs, the spirometer helps you improve repeatability and performance. 

Data sharing

The spirometer can download spirometry data into Vmax® Encore software and SentrySuite® software.


Direct printing option

A USB connection on the spirometer gives the option of directly printing on external printers.


Standards compliance

The system completely complies with ATS/ERS 2005 standards.


Convenient packaging

The spirometer comes in a carrying case with all of its accessories.


MicroLoop and MicroLab
Tests performed
Tests: FVC, SVC, optional pulse oximetry
FVC, SVC, optional pulse oximetry
Forced (FVC): FEV1, FVC, PEF, FEV1/FVC, FEV6, VC, FEV.75, FEV3, FEV.75/VC, FEV.75/FVC, FEV1/VC, (FER), FEV3/VC, FEV3/FVC, FEV.75/FEV6, FEV1/FEV6, FEF25 (MEF75), FEF50 (MEF50), FEF75 (MEF25), FEF25-75 (MMEF), FEF50/VC, FEF50/FVC, MMEF/FVC (FEF25-75/FVC), FIV1, FIVC, PIF, FIV1/FIVC (FIR), FIF25 (MIF75), FIF50 (MIF50), FIF75 (MIF25), R50 (FEF50/FIF50), MET25-75, FET, MVV (ind)
Relaxed (SVC): VT (TV), Ti, Te, Ti/Ttot, EVC, IVC, IC, VT/Ti (TV/Ti), IRV, ERV, FR
Volume range: 0.1–8 L (gold standard turbine 0.1–9.99 L)
Flow range: 0.2–15 L/s
Accuracy: +/-3% to ATS recommendations
Spirometry PC software
Requirements: Windows® 2000, XP, 7

SpO2 module (not in the U.S.)
General
SpO2 range/accuracy: 0–100% ±2 digits
Heart range/accuracy: 18–300 BPM ±1 digit
Test recording time: 20 sec–60 min
Data recording: SpO2: 3x %SpO2 per sec
BPM: 3x HR per sec
Storage: 2,000+ patient tests including flow/volume loops and volume/time graphs
Power supply: Input: 100–240 VAC 50–60 Hz
Output: 5 V 2.0 A
Battery pack: Rechargeable lithium polymer 3.7 V 1,600 mAh
Dimensions: 10.03" x 4.72" x 1.38" (8 cm x 12 cm x 2 cm)
Transducer: 1.9" x 2.36" x 3.54" (50 mm x 60 mm x 90 mm)
Transport and storage conditions
Operation temperature: 0–40 °C (32–+104 °F)
Weight, excluding transducer: 0.44 lb (200 g)
Operating humidity: 30–90%, non-condensing
Storage and transport temperature: -20–+70 °C
Storage and transport humidity: 10–90% RH